TM 9--2350--292--20--2
0667 00--40
DEEP WATER FORDING KIT -- CONTINUED
0667 00
Removal--Continued
VENTILATION BLOWER SEAL AND BOOM FOOT DRAIN SHUTOFF CLAMPS.
1. Loosen and remove shutoff clamps (12) from ventilation blower drain hose (13) and right and left boom cylinder
boot drain hoses (14).
NOTE
Note the quantity and position of shim(s) being removed
to ensure shim(s) are installed in the same position.
2. Remove three screws (3), three nuts (4), three flat washers (5), three lockwashers (6), ventilation blower assem-
bly (7) and shims (8) from elbow mount (9) and inlet port (10). Retain screws, nuts, ventilation blower assembly
and shims. Discard lockwashers.
3. Loosen screws and remove seal (11) from inlet port (10). Remove caulking compound from seal and inlet port.
4. Position shims (8) and ventilation blower assembly (7) on elbow mount (9) and at inlet port (10), secure with three
screws (3), three new lockwashers (6), three flat washers (5) and three nuts (4).
5. Remove tape from VENT BLOWER switch (1) on the Accessories Panel (2).