TM 9--2350--292--20--2
0699 00--2
FIXED FIRE EXTINGUISHER ACTUATOR CABLE ASSEMBLY REPAIR --
CONTINUED
0699 00
Disassembly--Continued
2. Remove anti--pilferage seal (3) from control valve (1). Discard anti--pilferage seal.
WARNING
To prevent accidental discharge of CO2, first disconnect
the cylinder assembly connected to pull cable. Failure to
comply may result in injury or death to personnel.
3. Remove three screws (4), three lockwashers (5) and cover plate (6) from control valve (1). Discard lockwashers.
4. Remove cable reel (7) from valve body (8). Loosen two set screws (9), remove cable assembly (10) from reel (7).
5. Disconnect conduit (11) from valve body (8).
Figure 371
7
9
10
11
8
7
1
6
3
5
4