TM 9--2350--292--20--20699 00--2FIXED FIRE EXTINGUISHER ACTUATOR CABLE ASSEMBLY REPAIR --CONTINUED0699 00Disassembly--Continued2. Remove anti--pilferage seal (3) from control valve (1). Discard anti--pilferage seal.WARNINGTo prevent accidental discharge of CO2, first disconnectthe cylinder assembly connected to pull cable. Failure tocomply may result in injury or death to personnel.3. Remove three screws (4), three lockwashers (5) and cover plate (6) from control valve (1). Discard lockwashers.4. Remove cable reel (7) from valve body (8). Loosen two set screws (9), remove cable assembly (10) from reel (7).5. Disconnect conduit (11) from valve body (8).Figure 3717910118716354