TM 9--2350--292--20--2
0699 00--3
FIXED FIRE EXTINGUISHER ACTUATOR CABLE ASSEMBLY REPAIR --
CONTINUED
0699 00
Disassembly--Continued
NOTE
There are two sets of remote control pull handles (interior
and exterior). Both sets of control handles are removed
in the same manner.
6. Remove quick--release pin (12) and lower interior control pull handles cover (13).
7. Remove anti--pilferage seal (14) from interior cable handle (15). Discard anti--pilferage seal.
8. Pull interior cable handle (15). Hold cable fastener assembly (16), remove cable handle (15).
9. Remove plug (17) from socket (18), remove cable assembly (10) from plug (17).
10. Disconnect conduit (19) from adapter (20).
11. Remove three screws (21) from pulley release mechanism (22), lift off exterior control pull handles cover (23).
12. Remove anti--pilferage seal (24) from exterior cable handle (25). Discard anti--pilferage seal.
13. Pull exterior cable handle (25). Hold cable fastener assembly (26), remove cable handle (25).
14. Remove plug (27) from socket (28), remove cable assembly (10) from plug (27).
Figure 369
INTERIOR
EXTERIOR
19
20
13
12
23
21
22
10
18
17
10
28
27
26
24
25
15
14
16