TM 9--2350--292--20--20699 00--8FIXED FIRE EXTINGUISHER ACTUATOR CABLE ASSEMBLY REPAIR --CONTINUED0699 00Assembly--ContinuedNOTESplice is positioned inside dual pull mechanism by pullingon ends of cable assembly.15. Position splice (44) against dual side of dual pull mechanism (32). Thread cable assembly (10) through socket(28) and install plug (27), leaving two inches (5.08 cm) of free cable between pulley release mechanism (22) andcable fastener assembly (26).16. Hold cable fastener assembly (26), install exterior cable handle (25).17. Thread cable assembly (10) through adapter (20), connect conduit (19).18. Thread cable assembly (10) through socket (18) and install plug (17), leaving two inches (5.08 cm) of free cablebetween adapter (20) and cable fastener assembly (16).19. Hold cable fastener assembly (16), install interior cable handle (15).20. Position splice (44) against single side of dual pull mechanism (32).21. Verify cable handles (15 and 25) are in correct position.Figure 369INTERIOREXTERIORSINGLESIDEDUALSIDE19202232102827262532151718101644