TM 9--2350--292--20--2
FIXED FIRE EXTINGUISHER ACTUATOR CABLE ASSEMBLY REPAIR --
CONTINUED
0699 00
Assembly--Continued
WARNING
To avoid discharge of CO
2
, make sure control valve as-
sembly has been reset to the SET position and that both
cable handles are returned to off position (seated) before
installing control valve. Failure to comply may result in
injury or death to personnel.
31. Connect hose assembly (48) to valve body (8).
32. Connect tube assembly (46) to adapter (47).
33. Install new anti--pilferage seal (3) through holes in two cover plate mounting screws (4) and lockpin finger loop
(54). DO NOT run seal wire through manual discharge center shaft hole.
34. Install control valve (1) on cylinder assembly (2).
35. Install two new anti--pilferage seals (24 and 14) on each of two cable handles (25 and 15).
36. Position exterior control pull handles cover (23) on pulley release mechanism (22), secure with three screws (21).
37. Raise interior control pull handles cover (13), secure with quick--release pin (12).
Figure 371
54
21
24
22
23
13
12
15
14
48
8
46
47
3
4
1
2
25
END OF TASK