TM 9--2350--292--20--2FIXED FIRE EXTINGUISHER ACTUATOR CABLE ASSEMBLY REPAIR --CONTINUED0699 00Assembly--ContinuedWARNINGTo avoid discharge of CO2, make sure control valve as-sembly has been reset to the SET position and that bothcable handles are returned to off position (seated) beforeinstalling control valve. Failure to comply may result ininjury or death to personnel.31. Connect hose assembly (48) to valve body (8).32. Connect tube assembly (46) to adapter (47).33. Install new anti--pilferage seal (3) through holes in two cover plate mounting screws (4) and lockpin finger loop(54). DO NOT run seal wire through manual discharge center shaft hole.34. Install control valve (1) on cylinder assembly (2).35. Install two new anti--pilferage seals (24 and 14) on each of two cable handles (25 and 15).36. Position exterior control pull handles cover (23) on pulley release mechanism (22), secure with three screws (21).37. Raise interior control pull handles cover (13), secure with quick--release pin (12).Figure 3715421242223131215144884647341225END OF TASK0699 00--11/12 blank