TM 9--2350--292--20--20699 00--9FIXED FIRE EXTINGUISHER ACTUATOR CABLE ASSEMBLY REPAIR --CONTINUED0699 00Assembly--Continued22. Thread cable assembly (10) through valve body (8), connect conduit (11).23. Insert end of cable assembly (10) into slot (45) in cable reel (7). Adjust cable length for five inches (12.7 cm) offree cable between point A where cable assembly (10) enters cavity of control valve body (8) and point B wherecable enters slot (45) in cable reel (7). Secure cable assembly (10) with two set screws (9).NOTEControl valve must be removed from cylinder assembly tocheck for correct actuator cable assembly installation.24. Disconnect tube assembly (46) from adapter (47).25. Disconnect hose assembly (48) from valve body (8).26. Position cable reel (7) in valve body (8). Cam side must be down. Top of actuator pin (49) must contact cam sur-face. Align set arrow on reel with set line on body.Figure 371BA2847467487104911109459