TM 9--2350--292--20--20699 00--5FIXED FIRE EXTINGUISHER ACTUATOR CABLE ASSEMBLY REPAIR --CONTINUED0699 00Disassembly--Continued19. Remove dual pull mechanism (32) from vehicle with four conduits (11, 19, 38 and 39) and four pulleys (34, 40, 41and 42).NOTETag conduits and pulleys to aid in assembly.20. Remove four conduits (11, 19, 38 and 39) and four pulleys (34, 40, 41 and 42) from dual pull mechanism (32).21. Separate two halves of dual pull mechanism (32), remove cable assembly (10).22. Remove adapter (37) from pulley (41).23. Inspect parts for damage and replace as required.Figure 36934191142103841373940374138321042111934394032