TM 9--2350--292--20--20701 00--2FIXED FIRE EXTINGUISHER MANUAL INTERLOCK SYSTEM COMPONENTSREPLACEMENT -- CONTINUED0701 00Installation1. Install bracket (19) with two screws (17) and two new lockwashers (18).2. Install two adapters (16) with two nuts (15).3. Install interlock switch assembly (10), bushing (14) and key washer (13) with lockwasher (12) and nut (11) (key-washer, lockwasher and nut are part of switch assembly).4. Connect two 54A circuit leads (7) to wiring harnesses 4W101 (9) and 4W127 (8) at interlock switch assembly (10).5. Install shield (3) with two screws (6), two new lockwashers (5) and two nuts (4).6. Install quick--release pin chain (2) on shield (3) with new rivet (1).Figure 369123456789101111141312181815162119201717NOTEFOLLOW--ON MAINTENANCE:Install personnel heater control box(WP 0248 00)Install actuator cable assembly(WP 0699 00)END OF TASK