TM 9--2350--292--20--2
FIXED FIRE EXTINGUISHER PULLEY RELEASE MECHANISM
REPLACEMENT
0702 00
THIS WORK PACKAGE COVERS:
Removal, Installation
INITIAL SETUP:
Tools and Special Tools
General mechanics tool kit (item 1, WP 0717 00)
Materials/Parts
Lockwashers (2) (item 78, WP 0718 00)
Gasket (item 114, WP 0718 00)
Equipment Conditions
Actuator cable assembly removed
(WP 0699 00)
Removal
1. Remove two nuts (1), two lockwashers (2), gasket (3) and pulley release mechanism (4). Discard lockwashers
and gasket.
2. Inspect parts for damage and replace as required.
Installation
Install pulley release mechanism (4) with new gasket (3), two new lockwashers (2) and two nuts (1).
Figure 369
4
3
1
1
2
2
NOTE
FOLLOW--ON MAINTENANCE:
Install actuator cable assembly
(WP 0699 00)
END OF TASK
0702 00--1/2 blank