TM 9--2350--292--20--20414 00--2AUXILIARY POWER UNIT AUXILIARY HOUSING REPLACEMENT --CONTINUED0414 00Removal--ContinuedCAUTIONPersonnel heater exhaust hose is connected to auxiliaryhousing. Hose disconnection cannot be accessed untilhousing is removed. Do not over extend exhaust hosewhile removing attaching hardware during housing re-moval. Failure to comply may cause equipment damage.3. Remove auxiliary housing (5) until exhaust hose (8) attaching hardware can be accessed.4. Remove two screws (9), two lockwashers (10) and gasket (11) securing exhaust hose (8) to auxiliary housing (5).Remove housing. Discard lockwashers and gasket.5. Inspect parts for damage and replace as required.Installation1. Install new gasket (11) and exhaust hose (8) on auxiliary housing (5) with two screws (9) and two new lockwash-ers (10).5891011