TM 9--2350--292--20--2
0414 00--2
AUXILIARY POWER UNIT AUXILIARY HOUSING REPLACEMENT --
CONTINUED
0414 00
Removal--Continued
CAUTION
Personnel heater exhaust hose is connected to auxiliary
housing. Hose disconnection cannot be accessed until
housing is removed. Do not over extend exhaust hose
while removing attaching hardware during housing re-
moval. Failure to comply may cause equipment damage.
3. Remove auxiliary housing (5) until exhaust hose (8) attaching hardware can be accessed.
4. Remove two screws (9), two lockwashers (10) and gasket (11) securing exhaust hose (8) to auxiliary housing (5).
Remove housing. Discard lockwashers and gasket.
5. Inspect parts for damage and replace as required.
Installation
1. Install new gasket (11) and exhaust hose (8) on auxiliary housing (5) with two screws (9) and two new lockwash-
ers (10).
5
8
9
10
11