TM 9--2350--292--20--2
0529 00--4
PERSONNEL HEATER ASSEMBLY REPLACEMENT -- CONTINUED
0529 00
Installation--Continued
6. Connect electrical wiring harness 4W124 connector P2 (10) to heater assembly (6).
7. Torque screw (7) securing clamp (8) to exhaust pipe (9) to 90--95 lb--in. (10--11 N m).
8. Install nipple (5), elbow (3) and cover (4) on heater assembly (6).
9. Connect fuel tube (2) to elbow (3).
10. Open fuel shutoff cock (1).
Figure 286
1
2
3
4
6
5
10
8
9
7
NOTE
FOLLOW--ON MAINTENANCE:
Connect battery power (WP 0256 00)
Operate personnel heater and check for proper opera-
tion (TM 9--2350--292--10)
Install right side gas particulate filter and frame
(WP 0706 00)
Install right side fire extinguisher and bracket
(WP 0472 00)
END OF TASK