TM 9--2350--292--20--20547 00--6AUXILIARY POWER UNIT HYDRAULIC PUMP REPAIR -- CONTINUED0547 00AssemblyNOTEAssembly procedures can be performed in a suitablework area (workbench) away from the APU.Perform step 1 and 2 to assemble fittings and hose forinstallation on input side of hydraulic pump.Perform steps 3 through 9 to assemble fittings for instal-lation on output side of hydraulic pump.1. Apply sealing compound to threads of hose assembly (25) and install hose assembly (25) in elbow (26).2. Install adapter (12) on elbow (26).3. Install nipple (35) and valve (32) in pipe tee (29).4. Install coupling half (30) into adapter (31) and adapter (31) into valve (32).5. Install coupling half (27) in elbow (28).6. Connect elbow (28) to pipe tee (29).7. Connect pipe elbow (34) to nipple (35).8. Connect nipple (33) to pipe elbow (34).9. Install pipe elbow (16) on nipple (33).Figure 29625261227282930313216333435