TM 9--2350--292--20--20548 00--2AUXILIARY POWER UNIT HYDRAULIC PUMP REPAIR (HATZ) -- CONTINUED0548 00Removal--Continued2. Remove two nuts (6), two lockwashers (7) and U--bolt (8) from bracket (9). Discard lockwashers.3. Remove screw (10), lockwasher (11), flat washer (12) and bracket (9) from APU assembly. Discard lockwasher.4. Disconnect tube elbow (13) from tube elbow (14).5. Disconnect tube elbow (14) from adapter union (15).6. Remove adapter union (15) and preformed packing (16) from pump (17). Discard preformed packing.NOTERefer to disassembly procedures to further disassemblethe removed fittings and hose on the input port side ofthe hydraulic pump.7. Disconnect tube elbow (18) from adapter (19).8. Remove adapter (19) and preformed packing (20) from pump (17). Discard preformed packing.10111217815161413918201976