TM 9--2350--292--20--20548 00--6AUXILIARY POWER UNIT HYDRAULIC PUMP REPAIR (HATZ) -- CONTINUED0548 00AssemblyNOTEAssembly procedures can be performed in a suitablework area (workbench) away from the APU.Perform steps 1 and 2 to assemble fittings and hose forinstallation on input side of hydraulic pump.Perform steps 3 through 8 to assemble fittings for instal-lation on output side of hydraulic pump.1. Apply sealing compound to threads of all fittings and hoses prior to assembly.2. Install hose assembly (26) on tube elbow (13).3. Install pipe nipple (34) and valve (32) in pipe tee (29).4. Install coupling half (30) on adapter (31) and adapter (31) into valve (32).5. Install coupling half (27) on elbow (28).6. Install elbow (28) in pipe tee (29).7. Install adapter (33) on pipe nipple (34).8. Connect tube elbow (18) to adapter (33).2613273128303229333418