Removal--Continued
2. Remove two nuts (6), two lockwashers (7) and U--bolt (8) from bracket (9). Discard lockwashers.
3. Remove screw (10), lockwasher (11) and bracket (9) from APU assembly. Discard lockwasher.
4. Disconnect adapter (12) from adapter union (13).
5. Remove adapter union (13) and preformed packing (14) from pump (15). Discard preformed packing.
NOTE
Refer to disassembly procedures to further disassemble
the removed fittings and hose on the input port side of
the hydraulic pump.
6. Disconnect pipe elbow (16) from adapter (17).
7. Remove adapter (17) and preformed packing (18) from pump (15). Discard preformed packing.
Figure 296
10
11
9
6
7
8
12
13
14
15
17
18
16