TM 9-2350-256-20-1
0052 00
Troubleshooting Procedure
Transmission Oil Temperature Gage
Symptom
Transmission oil temperature gage malfunctioning.
Malfunction
Transmission oil temperature gage does not operate. Do steps 1 thru 7.
CORRECTIVE ACTION
WARNING
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry contacts a metal surface a direct
short may result in instant heating of tools, damage to equipment, and injury or death to personnel.
1.
Remove three screws (1), three lockwashers (2), two screws (3), two lockwashers (4), and ground strap
(5) and release gage panel (6). Disconnect gage panel to bulkhead wiring harness from gage panel.
Place red lead of multimeter in socket K of wire 27 and black lead to ground. Turn MASTER switch on
and check for voltage. Turn MASTER switch OFF. If voltage is present, go to step 2. If voltage is not
present, troubleshoot power control lever circuit.
0052 00-2