0052 00
CORRECTIVE ACTION Continued
2.
Reconnect gage panel to bulkhead wiring harness to gage panel. Disconnect wire 27D from transmis-
sion oil temperature gage. Place red lead of multimeter in wire 27D and black lead to ground. Turn
MASTER switch on and check for voltage. Turn MASTER switch OFF. If voltage is present, go to step
3. If voltage is not present, repair/replace wire 27D of gage panel wiring harness (see WP 0193 00).
3.
Reconnect wire 27D to transmission oil temperature gage. Disconnect wire 324 from transmission oil
temperature gage. Turn MASTER switch on and check transmission oil temperature gage for operation.
Transmission oil temperature gage should read "0." Ground case of transmission oil temperature gage
and check gage for operation. Gage should read full scale. Turn MASTER switch OFF. If transmission
oil temperature gage reads correctly, go to step 4. If transmission oil temperature gage fails to read
correctly, replace transmission oil temperature gage (see WP 0157 00).
0052 00-3