SECTION V: CONTROLS AND LINKAGESTM 9-2350-256-207Disconnect connecting link (17) from lever (18) byremoving screw (19) and lockwasher (20).8Remove bracket (21) and bearing housing (22) byremoving two screws (23) and two lockwashers (24).9Remove bearing housing (25) by removing two screws(26) and two lockwashers (27).10 Slide two bearing housings (22 and 25) and washer(28) from shaft assembly (29).11 Remove two retainers (30) and two bearings (31) frombearing housings (22 and 25).12 Remove two screws (32), two lockwashers (33), twokeys (34), and two levers (35 and 18) from shaftassembly (29).9-147