SECTION V: TROUBLESHOOTINGTM 9-2350-256-20WARNINGRemove all jewelry such as rings, dogtags, bracelets, etc. If jewelry contactsa metal surface a direct short may resultin instant heating of tools, damage toequipment, and injury or death topersonnel.R Remove four screws (1) and four lockwashers (2), andrelease electrical accessories panel (3). Ground panel.Reconnect electrical accessories panel wiring harnessto electrical accessories panel. Disconnect wire 1 (fromsocket D) from generator cutout switch. Place red leadof multimeter in wire 1 and black lead to ground. TurnMASTER switch on and check for voltage. TurnMASTER switch OFF. If voltage is present, go to stepS. If voltage is not present repair/replace wire 1 of bilgepump main power wiring harness from socket D (seeparagraph 6-84).S Reconnect wire 1 (from socket D) to generator cutoutswitch. Disconnect wire 1 (from socket C) fromgenerator cutout switch. Place red lead of multimeteron generator cutout switch and black lead to ground.Turn MASTER switch on, open generator cutout switchand check for voltage. Turn MASTER switch OFF,close generator cutout switch. If voltage is present,repair/replace wire 1 of bilge pump main power wiringharness (see paragraph 6-84). If voltage is not present,replace generator cutout switch (see paragraph 6-9).2-137