SECTION V: TROUBLESHOOTINGTM 9-2350-256-20WARNINGRemove all jewelry such as rings, dog tags,bracelets, etc. If jewelry contacts a metalsurface a direct short may result in instantheating of tools, damage to equipment, andinjury or death to personnel.I Reconnect wire 25 to external vehicle horn.Disconnect ground wire from external vehicle horn.Place red lead of multimeter on terminal of hornand black lead to ground. Turn MASTER switch on,push horn switch, and check for voltage. TurnMASTER switch OFF. If voltage is present,repair/replace ground wire (see paragraph 6-20).If voltage is not present, replace external vehiclehorn (see paragraph 6-20).2-223