TM 9-2350-256-207Remove two screws (14), two lockwashers (15), breather (16), two gaskets (17), and spacer plate (18).8Remove air duct hose (19) by removing hose clamp (20).9Remove two self-locking nuts (21), flange adapter (22), and gasket (23).b. INSTALLATION1Install breather (16), two new lockwashers (15), two new gaskets (17), spacer plate (18), and two screws (14).Tighten screws.2Install new gasket (23), flange adapter (22), and two new self-locking nuts (21).3Install air duct hose (19) by installing hose clamp (20). Tighten hose clamp.4Install air duct hose (12) by installing hose clamp (13). Tighten hose clamp.5Install tube (10) by installing hose clamps (11) at each end. Tighten hose clamps.6Install loop clamp (9) and washer (8) with new self-locking nut (7).7Install air duct hose (5) by installing hose clamp (6). Tighten hose clamp.8Install air duct hose (3) by installing hose clamp (4). Tighten hose clamp.9Install tube (1) by installing hose clamps (2) at each end. Tighten hose clamps.NOTEFollow-on maintenance:Install powerplant (see paragraph 3-1)Close exhaust doors (see paragraph 9-61)Close transmission access door (see paragraph 9-55)3-27