TM 9--2350--292--20--10244 00--6PTO/ACCESSORY PANEL REPAIR -- CONTINUED0244 00Assembly--Continued4. Install sealing plugs (51) in terminal junctions (50) as required in locations previously noted.NOTEThere are two rack assemblies on the mounting panel.Both are assembled and installed in the same manner.Perform steps 5 and 6 to assemble and install either rackassembly.5. Install terminal junctions (50) on rack assembly (49).6. Install rack assembly (49) on mounting panel (45) with two screws (48).NOTEThere are two relays on the mounting panel. Both relaysare installed in the same manner. Perform step 7 toinstall either of these relays.7. Install relay (47) on mounting panel (45) with two screws (46).NOTEThere are five circuit breakers on the mounting panel. Allfive are installed in the same manner. Perform step 8 toinstall these circuit breakers.8. Install circuit breaker (44) on mounting panel (45) with two screws (42) and two new lockwashers (43).494850515051504446474746454243K1K2