TM 9--2350--292--20--1
0030 00--5
BILGE PUMP FAILS TO OPERATE -- CONTINUED
0030 00
F 1. Remove accessory panel (WP 0244 00).
2. Place one multimeter lead on terminal board
T16 terminal B and other lead on accessory
control panel receptacle J3 pin E. Check for
continuity.
Is continuity present?
CONTINUED FROM STEP E
Replace lead 450B
from terminal B to
receptacle J3 pin E
(WP 0244 00). Verify
fault is corrected.
yes
no
G Place one multimeter lead on terminal board T16
terminal F and other lead on terminal board T16
terminal B. Check for continuity.
Is continuity present?
Replace lead 450B
from terminal B
(WP 0244 00). Verify
fault is corrected.
yes
no
CONTINUED ON NEXT PAGE