TM 9--2350--292--20--10071 00--12SIGNALS FROM SENSOR IS BELOW ITS VALID RANGE, INDICATES BOTHCIRCUITS ARE OPEN, IS ABOVE ITS VALID RANGE, INDICATES CIRCUITSARE CLOSED, OR WAS NOT PROCESSED CORRECTLY -- CONTINUED0071 00CONTINUED FROM STEP I1. Replace sensor that is failing (4MT524 or4MT525 refer to WP 0684 00, 4S527 or4MT528 refer to WP 0690 00, 4MT529,4MT530, 4MT531 or 4MT532 refer to WP0688 00, 4MT533, 4MT534 or 4MT547 refer toWP 0688 00, or 4MT544 refer to WP 0687 00.2. Reconnect wiring harness 4W503 to sensor(WP 0679 00).3. Start Enhanced Diagnostics program(WP 0086 00) and run selftest.JDoes failing sensor now pass selftest?yesnoReplace remote termi-nal unit (WP 0675 00).Verify fault is corrected.Fault corrected.END OF TASK
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business