TM 9--2350--292--20--1
0071 00--12
SIGNALS FROM SENSOR IS BELOW ITS VALID RANGE, INDICATES BOTH
CIRCUITS ARE OPEN, IS ABOVE ITS VALID RANGE, INDICATES CIRCUITS
ARE CLOSED, OR WAS NOT PROCESSED CORRECTLY -- CONTINUED
0071 00
CONTINUED FROM STEP I
1. Replace sensor that is failing (4MT524 or
4MT525 refer to WP 0684 00, 4S527 or
4MT528 refer to WP 0690 00, 4MT529,
4MT530, 4MT531 or 4MT532 refer to WP
0688 00, 4MT533, 4MT534 or 4MT547 refer to
WP 0688 00, or 4MT544 refer to WP 0687 00.
2. Reconnect wiring harness 4W503 to sensor
(WP 0679 00).
3. Start Enhanced Diagnostics program
(WP 0086 00) and run selftest.
J
Does failing sensor now pass selftest?
yes
no
Replace remote termi-
nal unit (WP 0675 00).
Verify fault is corrected.
Fault corrected.
END OF TASK