TM 9--2350--292--20--1
0099 00--5
BOOM STAYLINE CABLES BECOME SLACK DURING LIVE BOOM
OPERATION OR BOOM CAN BE STOWED WITHOUT ACTIVATING THE
BOOM SAFETY VALVE CONTROL LEVER -- CONTINUED
0099 00
V
Are all arms, pivot pins, mounting pins, and cylin-
ders free of binding, missing parts, restrictions,
and damage?
CONTINUED FROM STEP B
no
yes
1. Remove air intake grilles beside both boom
stayline arms.
2. Inspect stayline arms, pivot pins, cylinder
mounting pins, and stayline cylinders for
binding, missing parts, restrictions, and
damage.
Free parts that are bound
or have restrictions.
Verify fault is corrected.
If parts cannot be freed
or are damaged or mis-
sing, notify Direct Support
Maintenance.
W
Are hoses free of leaks, restrictions, and damage?
Inspect stayline cylinder hoses for leaks, restric-
tions, and damage.
yes
no
Tighten leaking con-
nections and free
hoses of restrictions.
Verify fault is corrected.
If hoses cannot be
freed of restrictions or
are damaged, replace
hoses (WP 0566 00).
Verify fault is corrected.
Notify Direct Support
Maintenance.
FORWARD