TM 9--2350--292--20--10116 00--2STOPLIGHT ASSEMBLIES FAIL TO OPERATE -- CONTINUED0116 00noyesRepair (WP 0290 00) orreplace (WP 0314 00)harness 4W100. Verifyfault is corrected.noyesGo to Step H, number 3.Is 24 V dc present?1. Disconnect harness 3W142 P1 from bulkheaddisconnect.2. Turn MASTER switch ON and turn main lightswitch to SER DRIVE (TM 9--2350--292--10).3. Place multimeter red lead in harness 4W127P4 socket D and black lead to ground. Checkfor voltage.4. Turn MASTER switch OFF(TM 9--2350--292--10).BC1. Remove switch panel from bracket(WP 0242 00) and reconnect ground strap toswitch panel.2. Disconnect harness 4W105 P1 from switchpanel.3. Turn MASTER switch ON(TM 9--2350--292--10).4. Place multimeter red lead in harness 4W105 P1socket N and black lead to ground. Check forvoltage.5. Turn MASTER switch OFF(TM 9--2350--292--10).Is 24 V dc present?CONTINUED ON NEXT PAGECONTINUED FROM STEP A