TM 9--2350--292--20--10117 00--2STOPLIGHTS FAIL TO OPERATE -- CONTINUED0117 00noyesRepair (WP 0290 00) orreplace (WP 0314 00)harness 4W100. Verify fault iscorrected.CONTINUED ON NEXT PAGE1. Remove switch panel from bracket(WP 0242 00) and reconnect ground strap toswitch panel.2. Disconnect harness 4W105 P1 from switchpanel.3. Turn MASTER switch ON(TM 9--2350--292--10).4. Place multimeter red lead on harness 4W105P1 socket N and black lead to ground. Checkfor voltage.5. Turn MASTER switch OFF(TM 9--2350--292--10).Is 24 V dc present?CONTINUED FROM STEP B1. Disconnect harness 4W127 P1 from directionalsignal control assembly.2. Turn MASTER switch ON and turn main lightswitch to STOPLIGHT position(TM 9--2350--292--10).3. Place multimeter red lead in harness 4W127P1 socket D and black lead to ground. Checkfor voltage.4. Turn MASTER switch OFF(TM 9--2350--292--10).noyesGo to Step J.CIs 24 V dc present?D