TM 9--2350--292--20--10117 00--4STOPLIGHTS FAIL TO OPERATE -- CONTINUED0117 00CONTINUED FROM STEP GHCONTINUED ON NEXT PAGE1. Disconnect harness 4W127 P2 from switchpanel.2. Place one multimeter lead in harness 4W151 P1socket C and other lead on harness 4W151 J2pin B. Check for continuity.Is continuity present?noyesRepair (WP 0290 00) orreplace (WP 0242 00)harness 4W151. Verifyfault is corrected.noyesRepair (WP 0290 00) orreplace (WP 0317 00) harness4W105. Verify fault iscorrected.I1. Reconnect harness 4W151 P1 to switch S8.2. Disconnect both leads 75 and 75/16 fromstoplight switch.3. Place one multimeter lead in harness 4W105P1 socket D and other lead in lead 75/16connector socket. Check for continuity.4. Place one multimeter lead in harness 4W105P1 socket L and other lead in lead 75connector socket. Check for continuity.Is continuity present at both checks?