TM 9--2350--292--20--1
0116 00--3
STOPLIGHT ASSEMBLIES FAIL TO OPERATE -- CONTINUED
0116 00
CONTINUED FROM STEP C
D 1. Disconnect harness 4W151 P1 from switch S8.
2. Place one multimeter lead on harness
4W151 J4 pin N and other lead in harness
4W151 P1 socket F. Check for continuity.
Is continuity present?
no
yes
Repair (WP 0290 00) or
replace (WP 0242 00)
harness 4W151. Verify
fault is corrected.
no
yes
Replace switch S8
(WP 0242 00). Verify
fault is corrected.
E
F
Place one multimeter lead on S8 switch receptacle
pin F and other lead on switch S8 receptacle pin H.
Check for continuity.
Is continuity present?
Is continuity present?
no
yes
Repair (WP 0290 00) or
replace (WP 0242 00)
harness 4W151. Verify
fault is corrected.
1. Disconnect harness 4W127 P1 from switch
panel.
2. Place one multimeter lead in harness 4W151
P1 socket H and other lead on harness
4W151 J2 pin D. Check for continuity.
CONTINUED ON NEXT PAGE