TM 9--2350--292--20--10116 00--3STOPLIGHT ASSEMBLIES FAIL TO OPERATE -- CONTINUED0116 00CONTINUED FROM STEP CD 1. Disconnect harness 4W151 P1 from switch S8.2. Place one multimeter lead on harness4W151 J4 pin N and other lead in harness4W151 P1 socket F. Check for continuity.Is continuity present?noyesRepair (WP 0290 00) orreplace (WP 0242 00)harness 4W151. Verifyfault is corrected.noyesReplace switch S8(WP 0242 00). Verifyfault is corrected.EFPlace one multimeter lead on S8 switch receptaclepin F and other lead on switch S8 receptacle pin H.Check for continuity.Is continuity present?Is continuity present?noyesRepair (WP 0290 00) orreplace (WP 0242 00)harness 4W151. Verifyfault is corrected.1. Disconnect harness 4W127 P1 from switchpanel.2. Place one multimeter lead in harness 4W151P1 socket H and other lead on harness4W151 J2 pin D. Check for continuity.CONTINUED ON NEXT PAGE