TM 9--2350--292--20--10134 00--3TRANSMISSION OIL PRESSURE GAUGE FAILS TO OPERATE -- CONTINUED0134 00Is 24 V dc present?1. Disconnect harness 4W103 P1 from gaugepanel.2. Turn MASTER switch ON(TM 9--2350--292--10).3. Place multimeter red lead in harness 4W103P1 socket K and black lead to ground. Checkfor voltage.4. Turn MASTER switch OFF(TM 9--2350--292--10).noyesFCONTINUED ON NEXT PAGERepair (WP 0290 00) orreplace (WP 0316 00)harness 4W103. Verifyfault is corrected.CONTINUED FROM STEP EIs continuity present?1. Disconnect lead 27 from pressure gauge.2. Place one multimeter lead in lead 27 connectorsocket and one lead in harness 4W152 J1 pinK and check for continuity.3. Reconnect lead 27 to pressure gauge.noyesGRepair (WP 0290 00) orreplace (WP 0243 00)lead 27. Verify fault iscorrected.