TM 9--2350--292--20--1
0145 00--3
HIGH TEMP INDICATOR FAILS TO LIGHT WHEN PTO CLUTCH OIL
TEMPERATURE IS HIGH. ALL OTHER SYSTEMS OPERATE PROPERLY --
CONTINUED
0145 00
CONTINUED FROM STEP C
E
Is 24 V dc present?
no
yes
1. Turn MASTER switch ON
(TM 9--2350--292--10).
2. Place multimeter red lead on terminal 1 of
indicator DS4 and black lead to ground. Check
for voltage.
3. Turn MASTER switch OFF
(TM 9--2350--292--10).
Replace indicator DS4
(WP 0244 00). Verify fault
is corrected.
CONTINUED ON NEXT PAGE
F
Is continuity present?
no
yes
Place one multimeter lead on terminal 1 of indicator
DS4 and other lead on terminal board T19 terminal
K. Check for continuity.
Repair (WP 0290 00) or
replace (WP 0244 00) lead
10. Verify fault is corrected.
G
Is continuity present?
no
yes
Place one multimeter lead on T19 terminal K and
other lead on terminal board T19 terminal E.
Check for continuity.
Replace terminal board
T19 (WP 0244 00).
Verify fault is corrected.