TM 9--2350--292--20--10145 00--2HIGH TEMP INDICATOR FAILS TO LIGHT WHEN PTO CLUTCH OILTEMPERATURE IS HIGH. ALL OTHER SYSTEMS OPERATE PROPERLY --CONTINUED0145 00BIs continuity present?CONTINUED FROM STEP AnoyesCONTINUED ON NEXT PAGE1. Remove jumper wire from lead 525 andground.2. Open accessory control panel (WP 0242 00).3. Place one multimeter lead on lead 525connector at indicator DS4 terminal 2 and otherlead on diode T2 terminal D. Check forcontinuity.Repair (WP 0290 00) orreplace (WP 0244 00)lead 525 from indicator todiode T2 terminal D.Verify fault is corrected.CIs continuity present?noyesPlace one multimeter lead on diode T2 terminal Dand other lead on diode T2 terminal A. Check forcontinuity.Replace diode T2(WP 0244 00). Verifyfault is corrected.DIs continuity present?noyes1. Disconnect harness 2W601 P1 from accessorycontrol panel.2. Place one multimeter lead on accessory controlpanel receptacle J1 pin G and other lead ondiode T2 terminal A. Check for continuity.Repair (WP 0290 00) orreplace (WP 0244 00) lead525 from diode T2 terminalA to receptacle J1 pin G.Verify fault is corrected.