TM 9--2350--292--20--10182 00--4MAIN WINCH FAILS TO SHUT DOWN DURING MALFUNCTION --CONTINUED0182 00GIs 24 V dc present at both checks?CONTINUEDFROMSTEPDnoyes1. Remove subfloor plate 18 (WP 0454 00).2. Disconnect harness 2W612 connectors P1 andP2 from main winch power reduction manifold.3. Turn MASTER switch ON and hold WINCHTEST switch in the TEST position(TM 9--2350--292--10).4. Place multimeter red lead on harness 2W612connectors P1 and P2 socket 1 (one at a time)and black lead to ground. Check for voltage.5. Turn MASTER switch OFF(TM 9--2350--292--10).Repair (WP 0290 00) orreplace (WP 0292 01)harness 2W612. Verifyfault is corrected.HIs continuity present at both checks?noyesPlace one multimeter lead on wiring harness2W612 connectors P1 and P2 socket 2 (one at atime) and other lead to ground. Check continuity.Repair (WP 0290 00)or replace wiringharness 2W612(WP 0292 01). Verifyfault is corrected.Replace main winchpower reduction man-ifold (WP 0557 00).Verify fault is cor-rected.FORWARDEND OF TASK