TM 9--2350--292--20--10183 00--1MAIN WINCH FAILS TO SHUT DOWN WHEN WINCH TEST SWITCH IS HELDIN TEST POSITION.0183 00THIS WORK PACKAGE COVERS:Main Winch Fails To Shut Down When Winch Test Switch Is Held In Test PositionINITIAL SETUP:Tools and Special ToolsGeneral mechanic’s tool kit (item 1, WP 0717 00)Multimeter (item 84, WP 0717 00)Equipment ConditionsVehicle MASTER switch OFF (TM 9--2350--292--10)Hydraulic system operating (TM 9--2350--292--10)Personnel RequiredTwoIs either the LEVEL WINDER MALFUNCTION, WINCHDRUM MALFUNCTION, or PAYOUT LIMIT indicatorslit?Check winch indicators on hydraulic control panel.noyesABCONTINUED ON NEXT PAGEHold WINCH TEST switch in the TEST positionand watch SYSTEM WARNING indicator ongauge panel.Does indicator light?WARNINGRemove rings, bracelets, wristwatches,and neck chains before working on anyvehicle. Jewelry can catch on equip-ment and cause injury, or may shortacross an electrical circuit and causesevere burns or electrical shock.Go to Step H.noyesC1. Shut down hydraulics system, main engineand MASTER switch (TM 9--2350--292--10).2. Disconnect harness 4W618 P2 from harness4W617 J1.3. Turn MASTER switch ON(TM 9--2350--292--10).4. Place multimeter red lead in harness 4W618P2 pin H and black lead to ground. Check forvoltage.5. Turn MASTER switch OFF(TM 9--2350--292--10).Is 24 V dc present?Go to Step P