TM 9--2350--292--20--1
0183 00--5
MAIN WINCH FAILS TO SHUT DOWN WHEN WINCH TEST SWITCH IS HELD
IN TEST POSITION -- CONTINUED
0183 00
CONTINUED ON NEXT PAGE
J
Is continuity present?
no
yes
1. Disconnect harness 4W618 P2 from harness
4W617 J1.
2. Place one multimeter lead on harness 4W617
lead 359B connector terminal to WINCH
OVERRIDE switch and other lead on harness
4W617 J1 socket D. Check for continuity.
Repair (WP 0290 00) or
replace (WP 0330 00)
harness 4W617. Verify
fault is corrected.
CONTINUED FROM STEP I
K
Is continuity present?
no
yes
1. Open accessory control panel (WP 0290 00).
2. Disconnect harness 4W618 P1 from accessory
control panel.
3. Place one multimeter lead on harness 4W618
P2 pin D and other lead on harness 4W618 P1
socket 7. Check for continuity.
Repair (WP 0290 00) or
replace (WP 0331 00)
harness 4W618. Verify
fault is corrected.