TM 9--2350--292--20--10183 00--5MAIN WINCH FAILS TO SHUT DOWN WHEN WINCH TEST SWITCH IS HELDIN TEST POSITION -- CONTINUED0183 00CONTINUED ON NEXT PAGEJIs continuity present?noyes1. Disconnect harness 4W618 P2 from harness4W617 J1.2. Place one multimeter lead on harness 4W617lead 359B connector terminal to WINCHOVERRIDE switch and other lead on harness4W617 J1 socket D. Check for continuity.Repair (WP 0290 00) orreplace (WP 0330 00)harness 4W617. Verifyfault is corrected.CONTINUED FROM STEP IKIs continuity present?noyes1. Open accessory control panel (WP 0290 00).2. Disconnect harness 4W618 P1 from accessorycontrol panel.3. Place one multimeter lead on harness 4W618P2 pin D and other lead on harness 4W618 P1socket 7. Check for continuity.Repair (WP 0290 00) orreplace (WP 0331 00)harness 4W618. Verifyfault is corrected.