TM 9--2350--292--20--10183 00--8MAIN WINCH FAILS TO SHUT DOWN WHEN WINCH TEST SWITCH IS HELDIN TEST POSITION -- CONTINUED0183 00Is continuity present?CONTINUED FROM STEP Bnoyes1. Shut down hydraulics system, main engineand turn MASTER switch OFF(TM 9--2350--292--10).2. Disconnect harness 2W601 P1 from accessorycontrol panel.3. Remove subfloor plate 18 (WP 0454 00).4. Disconnect harness 2W601 P1 lead 359B frommain winch payin safety valve.5. Place one mulitmeter lead in harness 2W601P1 socket L and other lead on harness lead359B main winch payin safety valve connectorsocket. Check for continuity.Repair (WP 0290 00) orreplace (WP 0291 00)harness 2W601. Verifyfault is corrected.CONTINUED ON NEXT PAGEIs vehicle equipped with main winch powerreduction manifold?noyesGo to WP 0185 00.PQ