TM 9--2350--292--20--1
0185 00--2
MAIN WINCH POWER IS NOT REDUCED WHEN OVERRIDE SWITCH IS IN
OVERRIDE POSITION -- CONTINUED
0185 00
1. Reconnect wiring harness 2W612 connector
P8 to PMO pressure switch.
2. Disconnect wiring harness 2W612 connector
P7 from pressure switch on power reduction
manifold.
3. Turn MASTER switch ON, move WINCH
OVERRIDE switch to OVERRIDE and WINCH
TEST switch to TEST position and hold
(TM 9--2350--292--10).
4. Place multimeter red lead in socket B of wiring
harness 2W612 connector P7 and black lead
to ground. Check for voltage.
5. Release WINCH OVERRIDE and WINCH
TEST switches and turn MASTER switch OFF
(TM 92350--292--10).
CONTINUED FROM STEP B
no
yes
CONTINUED ON NEXT PAGE
Repair (WP 0290 00) or re-
place (WP 0292 01) wiring
harness 2W612. Verify fault
is corrected.
Is 24 V dc present?
C
Is 24 V dc present?
1. Reconnect wiring harness 2W612 lead 359B to
winch override switch terminal 3.
2. Disconnect wiring harness 2W612 connector
P8 from PMO pressure switch on power
reduction manifold.
3. Turn MASTER switch ON and move WINCH
OVERRIDE switch to OVERRIDE and WINCH
TEST switch to TEST position and hold.
4. Place multimeter red lead in socket B of wiring
harness 2W612 connector P8 and black lead to
ground. Check for voltage.
5. Release WINCH TEST and WINCH
OVERRIDE switches and turn MASTER switch
OFF (TM 9--2359--292--10).
D
no
yes
Repair (WP 0290 00) or replace
(WP 0292 01) wiring harness
2W612. Verify fault is corrected.
FORWARD