TM 9--2350--292--20--10185 00--2MAIN WINCH POWER IS NOT REDUCED WHEN OVERRIDE SWITCH IS INOVERRIDE POSITION -- CONTINUED0185 001. Reconnect wiring harness 2W612 connectorP8 to PMO pressure switch.2. Disconnect wiring harness 2W612 connectorP7 from pressure switch on power reductionmanifold.3. Turn MASTER switch ON, move WINCHOVERRIDE switch to OVERRIDE and WINCHTEST switch to TEST position and hold(TM 9--2350--292--10).4. Place multimeter red lead in socket B of wiringharness 2W612 connector P7 and black leadto ground. Check for voltage.5. Release WINCH OVERRIDE and WINCHTEST switches and turn MASTER switch OFF(TM 92350--292--10).CONTINUED FROM STEP BnoyesCONTINUED ON NEXT PAGERepair (WP 0290 00) or re-place (WP 0292 01) wiringharness 2W612. Verify faultis corrected.Is 24 V dc present?CIs 24 V dc present?1. Reconnect wiring harness 2W612 lead 359B towinch override switch terminal 3.2. Disconnect wiring harness 2W612 connectorP8 from PMO pressure switch on powerreduction manifold.3. Turn MASTER switch ON and move WINCHOVERRIDE switch to OVERRIDE and WINCHTEST switch to TEST position and hold.4. Place multimeter red lead in socket B of wiringharness 2W612 connector P8 and black lead toground. Check for voltage.5. Release WINCH TEST and WINCHOVERRIDE switches and turn MASTER switchOFF (TM 9--2359--292--10).DnoyesRepair (WP 0290 00) or replace(WP 0292 01) wiring harness2W612. Verify fault is corrected.FORWARD