TM 9--2350--292--20--1MAIN WINCH POWER IS NOT REDUCED WHEN OVERRIDE SWITCH IS INOVERRIDE POSITION -- CONTINUED0185 001. Reconnect wiring harness 2W612 connectorP8 to PMO pressure switch.2. Reconnect wiring harness 2W612 connectorP6 from PMO safety valve A.3. Disconnect wiring harness 2W612 connectorP5 from PMI safety valve B.4. Disconnect wiring harness 2W612 connectorP7 from PMI pressure switch.5. Place a jumper wire between socket B and Cof connector P7.6. Turn MASTER switch ON, move WINCHOVERRIDE switch to OVERRIDE and WINCHTEST to TEST position and hold.7. Place multimeter red lead in socket 1 ofconnector P5 and black lead to ground. Checkfor voltage.8. Release WINCH OVERRIDE and WINCHTEST switches and turn MASTER switch OFF(TM 92350--292--10).CONTINUED FROM STEP HIs 24 V dc present?InoyesRepair (WP 0290 00) or replace(WP 0292 01) wiring harness2W612. Verify fault is corrected.1. Reconnect wiring harness 2W612 connectorP7 to PMI pressure switch.2. Place one multimeter lead in socket 2 of wiringharness 2W612 connector P5 and the otherlead to ground.3. Check for continuity.Is continuity present?JnoyesClean wiring harness 2W612grounding surface(WP 0292 01). If properground cannot be obtained,repair (WP 0290 00) orreplace (WP 0292 01) wiringharness 2W612. Verify faultis corrected.Replace main winchpower reduction manifold(WP 0557 00). Verifyfault is corrected.END OF TASK0185 00--5/6 blank