TM 9--2350--292--20--10185 00--3MAIN WINCH POWER IS NOT REDUCED WHEN OVERRIDE SWITCH IS INOVERRIDE POSITION -- CONTINUED0185 001. Reconnect wiring harness 2W612 connectorP7 to PMI pressure switch.2. Disconnect wiring harness 2W612 connectorP4 from pressure switch PMO A on powerreduction manifold.3. Turn MASTER switch ON, move WINCHOVERRIDE switch to OVERRIDE and WINCHTEST switch to TEST position and hold.4. Place multimeter red lead in socket I of wiringharness 2W612 connector P4 and black leadto ground. Check for voltage.5. Release WINCH OVERRIDE and WINCHTEST switches and turn MASTER switch OFF(TM 92350--292--10).CONTINUED FROM STEP DCONTINUED ON NEXT PAGEIs 24 V dc present?EnoyesRepair (WP 0290 00) or replace(WP 0292 01) wiring harness2W612. Verify fault is corrected.1. Reconnect wiring harness 2W612 connectorP4 to PMO pressure switch A.2. Disconnect wiring harness 2W612 connectorP3 from PM1 pressure switch A on powerreduction manifold.3. Turn MASTER switch ON, move WINCHOVERRIDE switch to OVERRIDE and WINCHTEST switch to TEST position and hold.4. Place multimeter red lead in socket 1 of wiringharness 2W612 connector P3 and black leadto ground. Check for voltage.5. Release WINCH OVERRIDE and WINCHTEST switches and turn MASTER switch OFF(TM 92350--292--10).Is 24 V dc present?FnoyesRepair (WP 0290 00) or replace(WP 0292 01) wiring harness2W612. Verify fault is corrected.