TM 9--2350--292--20--2
EXHAUST SMOKE GENERATING SYSTEM FUEL TUBE ASSEMBLIES
REPLACEMENT -- CONTINUED
0669 00
Installation
1. Install elbow (11) on tee (7).
2. Install tube assembly (6) on solenoid valve assembly elbow (10) and elbow (11).
3. Install left exhaust manifold nozzle (9) in left exhaust manifold.
4. Install tube assembly (4) on tee (7) and left exhaust manifold nozzle (9).
5. Install right exhaust manifold nozzle (8) in right exhaust manifold.
6. Install tube assembly (3) on tee (7) and right exhaust manifold nozzle (8).
7. Secure tube assembly (6) with two new assembled--washer screws (1) and two clamps (5).
8. Secure two tube assemblies (3 and 4) with two new assembled--washer screws (1) and two clamps (2).
WARNING
Move vehicle out of building before attempting to check
system for operation/leaks. Extinguish all open flames in
the immediate area. Refer to TM 9--2350--292--10 for
operating system. Failure to comply may result in person-
nel injury.
NOTE
After performing maintenance or operation of the exhaust
smoke generating system, make sure the fuel shutoff
valve is in the closed position.
9. Check exhaust smoke generating system for leaks and proper operation (TM 9--2350--292--10).
Figure 362
3
4
1
2
1
1
6
7
8
9
10
11
2
5
1
5
NOTE
FOLLOW--ON MAINTENANCE:
Install engine deck assembly (WP 0417 00)
END OF TASK
0669 00--3/4 blank