TM 9--2350--292--20--2EXHAUST SMOKE GENERATING SYSTEM FUEL TUBE ASSEMBLIESREPLACEMENT -- CONTINUED0669 00Installation1. Install elbow (11) on tee (7).2. Install tube assembly (6) on solenoid valve assembly elbow (10) and elbow (11).3. Install left exhaust manifold nozzle (9) in left exhaust manifold.4. Install tube assembly (4) on tee (7) and left exhaust manifold nozzle (9).5. Install right exhaust manifold nozzle (8) in right exhaust manifold.6. Install tube assembly (3) on tee (7) and right exhaust manifold nozzle (8).7. Secure tube assembly (6) with two new assembled--washer screws (1) and two clamps (5).8. Secure two tube assemblies (3 and 4) with two new assembled--washer screws (1) and two clamps (2).WARNINGMove vehicle out of building before attempting to checksystem for operation/leaks. Extinguish all open flames inthe immediate area. Refer to TM 9--2350--292--10 foroperating system. Failure to comply may result in person-nel injury.NOTEAfter performing maintenance or operation of the exhaustsmoke generating system, make sure the fuel shutoffvalve is in the closed position.9. Check exhaust smoke generating system for leaks and proper operation (TM 9--2350--292--10).Figure 362341211678910112515NOTEFOLLOW--ON MAINTENANCE:Install engine deck assembly (WP 0417 00)END OF TASK0669 00--3/4 blank