TM 9-2350-256-20-1
0092 00
CORRECTIVE ACTION Continued
10. Place red lead of multimeter in socket C of wire 26B and black to ground. Turn MASTER switch on
and check for voltage. Turn MASTER switch OFF. If voltage is not present, go to step 17. If voltage is
present, go to step 11.
11. Place red lead of multimeter in socket D of wire T and black lead to ground. Turn MASTER switch on
and check for voltage. Turn MASTER switch OFF. If voltage is present, go to step 12. If voltage is not
present, go to step 15.
0092 00-8