CHAPTER 12: MAINTENANCE OF MAIN HYDRAUUC SYSTEMTM 9-2350-256-2012-8 REPLACE HYDRAULIC SUBPLATE ID PLATE-ContinuedNOTERemoval and installation procedures are the same for all plates.a. REMOVAL1 Remove four drivescrews (1) each from nine plates (2).2 Remove plate (3) by removing four nuts (4), four lockwashers (5), and two U-bolts (6).b. INSTALLATION1 Install plate (3) with two U-bolts (6), four new lockwashers (5), and four nuts (4).2 Install nine plates (2) with four new drivescrews (1) each.12-9 REPLACE HYDRAULIC OIL RESERVOIR STRAINERTHIS TASK COVERSa. Removalb. InstallationINITIAL SET4UPTools:Equipment Condition:Tool kit, general mechanic's (Appendix C, item 53)Rear intermediate right access floor plate removed(see paragraph 9-10)Parts:Filter (Appendix G, item 22)Gasket (Appendix G, item 59)Lockwashers (6) (Appendix G, item 130)12-36