CHAPTER 12: MAINTENANCE OF MAIN HYDRAUUC SYSTEM
TM 9-2350-256-20
12-8 REPLACE HYDRAULIC SUBPLATE ID PLATE-Continued
NOTE
Removal and installation procedures are the same for all plates.
a. REMOVAL
1 Remove four drivescrews (1) each from nine plates (2).
2 Remove plate (3) by removing four nuts (4), four lockwashers (5), and two U-bolts (6).
b. INSTALLATION
1 Install plate (3) with two U-bolts (6), four new lockwashers (5), and four nuts (4).
2 Install nine plates (2) with four new drivescrews (1) each.
12-9 REPLACE HYDRAULIC OIL RESERVOIR STRAINER
THIS TASK COVERS
a. Removal
b. Installation
INITIAL SET4UP
Tools:
Equipment Condition:
Tool kit, general mechanic's (Appendix C, item 53)
Rear intermediate right access floor plate removed
(see paragraph 9-10)
Parts:
Filter (Appendix G, item 22)
Gasket (Appendix G, item 59)
Lockwashers (6) (Appendix G, item 130)
12-36