SECTION V: TROUBLESHOOTINGTM 9-2350-256-20WARNINGRemove all jewelry such as rings, dog tags,bracelets, etc. If jewelry contacts a metalsurface a direct short may result in instantheating of tools, damage to equipment, andinjury or death to personnel.NOTEDo steps A and B for all symptoms.ADisconnect wire 38 from dome light. Place red lead ofmultimeter in wire 38 and black lead to ground. TurnMASTER switch on and check for voltage. TurnMASTER switch OFF. If voltage is present, go to stepB. If voltage is not present, go to step C for left frontand left rear dome lights and go to step G for centerand right front dome lights.BRemove eight screws (1) and door assembly (2).Remove lamp from socket assembly. Turn MASTERswitch on. Place red lead of multimeter on contact incenter of socket and black lead to ground. Check forvoltage. Turn MASTER switch OFF. If voltage is notpresent, replace dome light assembly (see paragraph6-34). If voltage is present, replace lamp (seeparagraph 6-34).2-241