SECTION V: TROUBLESHOOTING
TM 9-2350-256-20
WARNING
Remove all jewelry such as rings, dog tags,
bracelets, etc. If jewelry contacts a metal
surface a direct short may result in instant
heating of tools, damage to equipment, and
injury or death to personnel.
NOTE
Do steps A and B for all symptoms.
A
Disconnect wire 38 from dome light. Place red lead of
multimeter in wire 38 and black lead to ground. Turn
MASTER switch on and check for voltage. Turn
MASTER switch OFF. If voltage is present, go to step
B. If voltage is not present, go to step C for left front
and left rear dome lights and go to step G for center
and right front dome lights.
B
Remove eight screws (1) and door assembly (2).
Remove lamp from socket assembly. Turn MASTER
switch on. Place red lead of multimeter on contact in
center of socket and black lead to ground. Check for
voltage. Turn MASTER switch OFF. If voltage is not
present, replace dome light assembly (see paragraph
6-34). If voltage is present, replace lamp (see
paragraph 6-34).
2-241