CHAPTER 6: MAINTENANCE OF ELECTRICAL SYSTEMS AND CIRCUITS TM 9-2350-256-206-41 REPLACE/REPAIR BATTERIES TO MASTER RELAY, VOLTAGE REGULATORS, SLAVERECEPTACLE, AND ENGINE DISCONNECT WIRING HARNESS (DUAL VOLTAGE) (11672413)-Continueda. REMOVAL1 Remove eight clamps (13) by removing screw (14) and lockwasher (15) from each.2 Disconnect connector (1) from main engine voltage regulator (16).3 Disconnect connector (2) from master relay (17).4 Disconnect two leads (3 and 4) from slavereceptacle (18) by removing screw (19) andlockwasher (20).5 Disconnect connector (5) from main enginedisconnect (19).6 Disconnect two connectors (6 and 7) frombulkhead to main engine bracket and rear fueltank transmitter wiring harness (20).7 Disconnect two connectors (8 and 9) frombatteries (21) by pulling back rubber insulator (22)and removing bolt (23) and nut (24).8 Disconnect connector (10) from bulkhead to APU,master relay, and rigger's lights wiring harness (25).6-84