TM 9--2350--292--20--10090 00--6SLOW OR NO HYDRAULIC COMPONENT OPERATION WITH HYDRAULICSELECTOR SET IN AUXILIARY POSITION -- CONTINUED0090 00CONTINUED FROM STEP FCONTINUED ON NEXT PAGEIs pressure above 1650 psi?noyes1. Start Enhanced Diagnostics Program (WP0086 00) and select the correspondingsymptom.2. Start the APU (TM 9--2350--292--10).3. Place the system selector in the AUX position.4. Place all other control handles in the center(neutral) position. Read pressure at APUTEST port on the hydraulic control valvemanifold assembly.5. Shut down the APU (TM 9--2350--292--10).Go to Step M.Is pressure above 1650 psi?noyes1. Shift system selector to the fuel transferposition.2. Start the APU (TM 9--2350--292--10) and readpressure at APU TEST port on the hydrauliccontrol valve manifold assembly.3. Shut down the APU (TM 9--2350--292--10).Fault corrected. If anauxiliary component failsto operate, go to QuickGuide and find appro-priate troubleshooting.KL