TM 9--2350--292--20--10090 00--3SLOW OR NO HYDRAULIC COMPONENT OPERATION WITH HYDRAULICSELECTOR SET IN AUXILIARY POSITION -- CONTINUED0090 00CONTINUED FROM STEP ECONTINUED ON NEXT PAGEIs reading on gauge 1650--1750 psi?noyes1. Remove hydraulic control valve manifoldassembly shields (WP 0519 00).2. Install a 4000 psi testing gauge assembly in theAPU TEST port on the hydraulic control valvemanifold assembly.3. Start the APU (TM 9--2350--292--10).4. Place the system selector in the AUX position.5. Place all other control handles in the center(neutral) position. Read gauge.6. Shut down the APU (TM 9--2350--292--10).Go to Step I.Is reading on gauge 1650--1750 psi?noyes1. Shift system selector to the fuel transferposition.2. Start the APU (TM 9--2350--292--10) and readgauge.3. Shut down the APU (TM 9--2350--292--10).Fault corrected. If anauxiliary component failsto operate, go to QuickGuide and find appro-priate troubleshooting.FORWARDFIs vehicle equipped with Enhanced DiagnosticSystem?GHnoyesGo to Step K.WARNING