TM 9--2350--292--20--1SLOW OR NO HYDRAULIC COMPONENT OPERATION WITH HYDRAULICSELECTOR SET IN AUXILIARY POSITION -- CONTINUED0090 00MAre both readings above 1650 psi?CONTINUED FROM STEP K AND Lnoyes1. Remove hydraulic control valve manifoldassembly shields (WP 0519 00).2. Disconnect hoses from ports AUX and FT onthe hydraulic control valve manifold assembly.3. Plug hoses and manifold.4. Start the APU (TM 9--2350--292--10).5. Place the system selector valve in the AUXposition and read the pressure of the APU testport.6. Shift the system selector valve to the fueltransfer position. Record pressure readings.Replace system selectorvalve (WP 0562 00).Verify fault is corrected.WARNINGGo to Step J.END OF TASK0090 00--7/8 blank