TM 9--2350--292--20--1NO POWER WHEN MASTER SWITCH IS TURNED ON -- CONTINUED0126 00noyesRIs 24 V dc present?CONTINUED FROM STEP QRepair (WP 0290 00) orreplace (WP 0309 00)harness 3W217. Verifyfault is corrected.1. Reconnect harness 3W217 lead 81 to masterrelay.2. Disconnect harness 3W217 lead 48 frombulkhead disconnect.3. Turn MASTER switch ON(TM 9--2350--292--10).4. Place multimeter red lead on harness 3W217lead 48 connector pin A and black lead toground. Check for voltage.5. Turn MASTER switch OFF(TM 9--2350--292--10).SIs 24 V dc present?1. Reconnect harness 3W217 lead 48 to bulkheaddisconnect.2. Disconnect harness 4W105 P1 from switchpanel.3. Turn MASTER switch ON(TM 9--2350--292--10).4. Place multimeter red lead in harness 4W105 P1socket M and black lead to ground. Check forvoltage.5. Turn MASTER switch OFF(TM 9--2350--292--10)noyesRepair (WP 0290 00) orreplace (WP 0317 00)harness 4W105. Verifyfault is corrected.Replace switch panel(WP 0242 00). Verifyfault is corrected.END OF TASK0126 00--11/12 blank