0390
00-2
PIVOT ARM ASSEMBLY REPAIR -- CONTINUED
0390
00
Disassembly
NOTE
It is not necessary to remove pivot arm assembly to re-
move the three lubrication fittings.
1.
Remove three lubrication fittings (4) from pivot arm assembly (1).
NOTE
Perform step 2 only if pivot arm assembly shoulder pin or
pins are damaged.
2.
Remove two shoulder pins (5) from pivot arm assembly (1).
WARNING
3.
Clean all components with dry - cleaning solvent.
4.
Inspect all components for wear, pitting or other damage. Discard worn or damaged components.
Assembly
1.
Install two shoulder pins (5) in pivot arm assembly (1) (shoulder pins (5) must extrude 3/4 in. out of pivot arm as-
sembly (1)).
2.
Install three lubrication fittings (4) in pivot arm assembly (1).
Figure 178
1
4
5