TM 9--2350--292--20--2
0452 00--8
DRAIN VALVES, CONTROLS AND RELATED PARTS REPLACEMENT--
CONTINUED
0452 00
Installation--Continued
20. Install detent plate (9) on support (10) with two screws (7) and two new lockwashers (8).
21. Move lever (4) to CLOSED position.
22. Loosen two clevis nuts (30) and adjust two clevises (3) until two pins (2) can be inserted into two clevises (3) and
lever (4).
23. Tighten two clevis nuts (30).
24. Connect two clevises (3) to lever (4) with two straight headed pins (2) and two new cotter pins (1).
Figure 230
8
9
1
2
3
3
7
NOTE:
LEVER (4) SHOWN
REMOVED FOR
CLARITY.
FRONT
BULKHEAD
4
2
1
10
30
30
NOTE
FOLLOW--ON MAINTENANCE:
Install left air cleaner intake hoses and tube
assemblies, if removed (WP 0212 00)
Install storage rack assembly, if removed
(WP 0463 00)
Install powerpack, if removed (WP 0188 00)
Install main winch and spade assembly, if
removed (WP 0497 00)
Install subfloor plates #13, #19 and #24,
(WP 0454 00)
END OF TASK